Determination of Plywood Bonding Strength by Boiling Test Part 4

Determination of Plywood Bonding Strength by Boiling Test Part 4

Class III plywood: The samples were immersed in water at 63 3 C for 2 hours, then dried in air convection drying box at 63 3 C separately for 1 hour, then removed and placed at room temperature for 10 minutes.

如无特殊说明,文章均为本站原创,转载请注明出处。If there are no special instructions, the articles are original, if you want to use or reproduce, please indicate the original source www.plywoodinspection.com,If you find that our articles infringe on your copyrights and interests, please email us at info@plywoodinspection.com in time and we will delete it at the first time.