MDF GRADER TEST AND INSPECTION

MDF GRADER TEST AND INSPECTION

Thickness (mm)
Property Test Method Units 12.0 15.0 18.0
Density Kg/m3 520-540 520-540 520-540
Internal Resistance EN319 N/mm2 0.35 0.35 0.35
Modulus of rupture EN310 N/mm2 15.0 15.0 15.0
Modulus of Elasticity EN310 N/mm2 1500 1500 1500
Screw resistance – Face EN320 N 400 400
Screw resistance – Edge EN320 N 250 250
Moisture EN322 % 5-9 5-9 5-9
Thickness Tolerance EN324-1 mm +/-0.20 +/-0.20 +/-0.20
Swelling (24hrs) EN317 % 15.0 12.0 10.0
DIMENSIONAL STABILITY
Length EN318 % 0.6 0.6 0.6
Thickness EN318 % 6.0 6.0 6.0
如无特殊说明,文章均为本站原创,转载请注明出处。If there are no special instructions, the articles are original, if you want to use or reproduce, please indicate the original source www.plywoodinspection.com,If you find that our article infringes on your rights and interests, please email us in time and we will delete it at the first time.